Overview
10-150kVA Modular
Compact, rack-mounted UPS with 2U power modules (20/25/30kVA) for high-density, scalable power. Ideal for data centers with intelligent charging, flexible 3/3, 3/1, 1/1 configurations, smart sleep mode, and IoT-ready touchscreen. High reliability with optional neutral-free battery connection.
Features
General Specifications
- Rack modular design – modular design, compatible with 19” standard rack cabinet, convenient to be integrated with servers
- High power density – 20/25/30kVA (20/25/30kW) power module in 2U height, saving great amount of space, easy for capacity expansion
- Integrated solution for data center – UPS can be integrated with battery cabinet, PDU and external maintenance bypass, offering excellent choice for data center
- Intelligent charging management – the system intelligently controls the whole process of the charging and discharging, effectively improving the life time of the battery
- Flexible configuration – the system can be configured to 3/3, 3/1 and 1/1
- Friendly interface – touch screen colored LCD with graphic display, more information displayed and easier for customer to operate and IoT function
- Smart sleep function – system can intelligently shutdown some power modules to increase total load rate, achieving higher efficiency
- Self-aging mode – energy internal circle technology, system can run with full load, saving more than 90% energy
- Highly reliable and adaptable – high reliability and environment adaptability, with protection of components level, also supporting battery connection without Neutral
Technical specifications
UPS 10 – 150 kVA Modular – MTW Rack-Modular Series – technical data
| Model | MTW20/10X1 | MTW40/10X1 | MTW60/10X1 | MTW30/15X1 | MTW60/15X1 | MTW90/15X1 |
|---|---|---|---|---|---|---|
| Rated power | 20 kVA / 20 kW | 40 kVA / 40 kW | 60 kVA / 60 kW | 30 kVA / 40 kW | 60 kVA / 80 kW | 90 kVA / 120 kW |
| Power module capacity | TPW10 | TPW10 | TPW10 | TPW15 | TPW15 | TPW15 |
| Input | ||||||
| Input | 3P + N + PE, L + N + PE | |||||
| Rate voltage | 3-phase input: 380/400/415 VAC (L-L); 1-phase input: 220/230/240 VAC (L-N) | |||||
| Input power factor | > 0.99 | |||||
| Current distortion | THDi < 2% (100% linear load) | |||||
| Voltage range | 3-phase input: 304 – 478 VAC (L-L) full load, 304 – 228 VAC (L-L) power derate from 100% to 75%; 1-phase input: 176 – 276 VAC (L-L) full load, 176 – 132 VAC (L-L) power derate from 100% to 75% | |||||
| Frequency range | 40 – 70 Hz | |||||
| Battery | ||||||
| Rate voltage | TPW10: 20 – 44 batteries, 3 wires (standard) / 2 wires (optional). TPW15: 32 – 44 batteries settable (30 – 32 batteries: UPS PF derate to 0.8; 34 batteries: UPS PF derate to 0.9; 36 – 50 batteries: UPS PF is 1.0); 3 wires (standard) ±240 VDC / 2 wires (optional) 480 VDC | |||||
| Charging capacity | Max. 100% × Pout (limited by input current) | |||||
| Charge accuracy | ±1% | |||||
| Bypass | ||||||
| Rate voltage | 3-phase input: 380/400/415 VAC (L-L); 1-phase input: 220/230/240 VAC (L-N) | |||||
| Voltage range | −40% – +25%, settable, default −20% / +15% | |||||
| Frequency range | Settable (±1 Hz, ±3 Hz, ±5 Hz) | |||||
| Overload | 110% long time operation, 110% < load < 125% 5 mins, 125% < load < 150% 1 min, > 150% 1 second | |||||
| Inverter | ||||||
| Rate voltage | 3-phase output: 380/400/415 VAC (L-L); 1-phase output: 220/230/240 VAC (L-N) | |||||
| Rate frequency | 50 Hz / 60 Hz | |||||
| Output power factor | 1 | |||||
| Voltage accuracy | ±1.0% | |||||
| Load response | < 5% (20% – 80% – 20% step load) | |||||
| Recovery time | < 20 ms (0% – 100% – 0% step load) | |||||
| Output THDv | < 1% (linear load), < 5% (non-linear load according to IEC 62040-3) | |||||
| Overload | 110%, 1 hour; 125%, 10 mins; 150%, 1 min; > 150%, 200 ms | |||||
| Frequency accuracy | 0.1% | |||||
| Synchronize window | Settable, ±0.5 Hz – ±5 Hz, default ±3 Hz | |||||
| Slew rate | Settable, ±0.5 Hz/s – ±3 Hz/s, default ±0.5 Hz/s | |||||
| Crest factor | 3:1 | |||||
| Phase accuracy | 120° ± 0.5° | |||||
| System | ||||||
| Efficiency – normal mode | > 96.5% | |||||
| Efficiency – battery mode | up to 95.3% | up to 95.3% | up to 95.3% | up to 95.5% | up to 95.5% | up to 95.5% |
| Display | LED + 7 inch touch LCD | |||||
| Certification – safety | IEC62040-1, IEC60950-1 | |||||
| Certification – EMS | IEC62040-2, IEC60950-4-2 (ESD); IEC61000-4-3 (RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | |||||
| IP degree | IP20 | |||||
| Noise (dB) (1 meter) | 62 dB @ 100% load, 58 dB @ 45% load | |||||
| Operation temperature | 0 – 40 °C | |||||
| Humidity | 0 – 95% (non condensing) | |||||
| Altitude | < 1000 m; 1000 – 2000 m power derates 1% every 100 m | |||||
| Configuration | USB, RS232, RS485, dry contact, cold start | |||||
| Option | SNMP card, AS400 card, parallel kit, LBS, air filter | |||||
| Physical | ||||||
| Cabinet H × W × D (mm) | 307 × 442 × 711 | 485 × 442 × 711 | 976 × 442 × 660 | 307 × 442 × 711 | 797 × 442 × 660 | 976 × 442 × 660 |
| Cabinet, wheels not included (mm) | 307 × 442 × 711 | 485 × 442 × 711 | 883 × 442 × 660 | 307 × 442 × 711 | 705 × 442 × 660 | 883 × 442 × 660 |
| Module (mm) | 86 × 400 × 495 (2U) | |||||
| Cabinet weight (kg) | 39 | 52 | 88 | 39 | 64 | 88 |
| Module weight (kg) | 12 | 14 | 16 | 12 | 14 | 16 |
| Model | MTW40/20X1 | MTW80/20X1 | MTW120/20X1 | MTW50/25X1 | MTW100/25X1 | MTW150/25X1 |
|---|---|---|---|---|---|---|
| Rated power | 40 kVA / 40 kW | 80 kVA / 80 kW | 120 kVA / 120 kW | 50 kVA / 50 kW | 100 kVA / 100 kW | 150 kVA / 150 kW |
| Power module capacity | TPW20 | TPW20 | TPW20 | TPW25 | TPW25 | TPW25 |
| Input | ||||||
| Input | 3P + N + PE, L + N + PE | |||||
| Rate voltage | 3-phase input: 380/400/415 VAC (L-L); 1-phase input: 220/230/240 VAC (L-N) | |||||
| Input power factor | > 0.99 | |||||
| Current distortion | THDi < 2% (100% linear load) | |||||
| Voltage range | 3-phase input: 304 – 478 VAC (L-L) full load, 304 – 228 VAC (L-L) power derate from 100% to 75%; 1-phase input: 176 – 276 VAC (L-L) full load, 176 – 132 VAC (L-L) power derate from 100% to 75% | |||||
| Frequency range | 40 – 70 Hz | |||||
| Battery | ||||||
| Rate voltage | 32 – 44 batteries settable (30 – 32 batteries: UPS PF derate to 0.8; 34 batteries: UPS PF derate to 0.9; 36 – 50 batteries: UPS PF is 1.0); 3 wires (standard) ±240 VDC / 2 wires (optional) 480 VDC | |||||
| Charging capacity | Max. 100% × Pout (limited by input current) | |||||
| Charge accuracy | ±1% | |||||
| Bypass | ||||||
| Rate voltage | 3-phase input: 380/400/415 VAC (L-L); 1-phase input: 220/230/240 VAC (L-N) | |||||
| Voltage range | −40% – +25%, settable, default −20% / +15% | |||||
| Frequency range | Settable (±1 Hz, ±3 Hz, ±5 Hz) | |||||
| Overload | 110% long time operation, 110% < load < 125% 5 mins, 125% < load < 150% 1 min, > 150% 1 second | |||||
| Inverter | ||||||
| Rate voltage | 3-phase output: 380/400/415 VAC (L-L); 1-phase output: 220/230/240 VAC (L-N) | |||||
| Rate frequency | 50 Hz / 60 Hz | |||||
| Output power factor | 1 | |||||
| Voltage accuracy | ±1.0% | |||||
| Load response | < 5% (20% – 80% – 20% step load) | |||||
| Recovery time | < 20 ms (0% – 100% – 0% step load) | |||||
| Output THDv | < 1% (linear load), < 5% (non-linear load according to IEC 62040-3) | |||||
| Overload | 110%, 1 hour; 125%, 10 mins; 150%, 1 min; > 150%, 200 ms | |||||
| Frequency accuracy | 0.1% | |||||
| Synchronize window | Settable, ±0.5 Hz – ±5 Hz, default ±3 Hz | |||||
| Slew rate | Settable, ±0.5 Hz/s – ±3 Hz/s, default ±0.5 Hz/s | |||||
| Crest factor | 3:1 | |||||
| Phase accuracy | 120° ± 0.5° | |||||
| System | ||||||
| Efficiency – normal mode | up to 96.5% | |||||
| Efficiency – battery mode | up to 96.5% | |||||
| Display | LED + 7 inch touch LCD | |||||
| Certification – safety | IEC62040-1, IEC60950-1 | |||||
| Certification – EMS | IEC62040-2, IEC60950-4-2 (ESD); IEC61000-4-3 (RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | |||||
| IP degree | IP20 | |||||
| Noise (dB) (1 meter) | 62 dB @ 100% load, 58 dB @ 45% load | |||||
| Operation temperature | 0 – 40 °C | |||||
| Humidity | 0 – 95% (non condensing) | |||||
| Altitude | < 1000 m; 1000 – 2000 m power derates 1% every 100 m | |||||
| Configuration | USB, RS232, RS485, dry contact, cold start | |||||
| Option | SNMP card, AS400 card, parallel kit, LBS, air filter | |||||
| Physical | ||||||
| Cabinet H × W × D (mm) | 307 × 442 × 711 | 797 × 442 × 660 | 976 × 442 × 660 | 307 × 442 × 711 | 797 × 442 × 660 | 976 × 442 × 660 |
| Cabinet, wheels not included (mm) | 307 × 442 × 711 | 705 × 442 × 660 | 883 × 442 × 660 | 307 × 442 × 711 | 705 × 442 × 660 | 883 × 442 × 660 |
| Module (mm) | 86 × 400 × 495 (2U) | |||||
| Cabinet weight (kg) | 39 | 64 | 88 | 39 | 64 | 88 |
| Module weight (kg) | 12 | 14 | 16 | 12 | 14 | 16 |
Downloads
Datasheets & manuals
Official Deltron documents for UPS 10 – 150 kVA Modular – MTW Rack-Modular Series. All files are PDF.
Related products
More UPS models
1-3kVA
Deltron 101 Series
High-Efficiency Power Protection
View details
6-10kVA
Deltron 106 Series
High-Efficiency Power Protection
View details
10-30kVA
DS Power H
The new DS Power range UPS uses the latest DSP technology to be programmed to suit a wide variety of electrical environments without impending its performance. With the DS Power range, efficiency, reliability and functionality are enhanced to levels unattainable with the old analogue technology. This technology does not only create significant increase in MTBF, but the capability of DSP to accurately manipulate signals at very high speed permits all the UPS subsystems to be controlled with greatly increased precision.
View details